LACT Units
Lease automatic custody transfer units fabricated, assembled and tested in our Houston shop to your design.
Built to Your Design in Houston
A LACT (lease automatic custody transfer) unit measures crude oil or condensate as it leaves the lease and passes to the purchaser or the transporting carrier. Because each barrel that crosses a LACT unit is bought and sold on its measurement ticket, the unit has to be built to the design the producer, purchaser and carrier agree on.
Fab Industries has been a Houston fabrication shop for the oil and gas industry for more than 40 years. Our qualified welders, machinists and assembly and test crews work under one roof in a 40,000-square-foot shop with overhead cranes from 10 to 50 tons, so the work is machined, welded, assembled and tested in-house before it ships.
Fab fabricates LACT units to your drawings and specifications. Our crews fabricate the skid and piping, mount and connect the components, and assemble and test the unit before it ships. For a plain-language overview of how a LACT unit works, see What Is a LACT Unit?
What API Means by a LACT System
API MPMS Chapter 6.4A
The American Petroleum Institute’s Manual of Petroleum Measurement Standards (MPMS) Chapter 6.4A covers the selection, installation and operation of lease automatic custody transfer metering systems. It replaced the older Chapter 6.1 and is read together with Chapter 6.1A, which covers general considerations for all liquid metering systems.
API describes a LACT system as an integrated system of primary, secondary and tertiary measurement components, along with piping and valving, that determines the custody transfer quantity, the quality and the associated data recorded on the measurement ticket. A LACT unit also includes equipment not always found on a pipeline liquid meter station, such as pumps and motors, pump controls, air eliminators, diverter valves and water-cut analyzers.
What Goes on a LACT Unit
The exact equipment list comes from your design. API notes that any component not needed for quantity or quality measurement or control may be left off. Typical items include:
- Charge pump and motor to move oil from the lease tanks through the unit
- Strainer to protect the meter and valves from debris
- Air eliminator to remove entrained vapor ahead of the meter
- S&W (sediment and water) monitor or water-cut analyzer to detect oil that is not merchantable
- Diverter valve that sends off-spec oil back for treatment instead of into the pipeline
- Sampler and sample container that collect a representative sample for quality testing
- Custody transfer meter: Positive Displacement, Turbine or Coriolis
- Temperature and pressure measurement for volume correction
- Prover connections and isolation valves so the meter can be proved in place
- Back-pressure and check valves, and the flow computer or controller that produces the ticket
From Lease Tank to Measurement Ticket
1. Transfer starts
When the lease tank reaches its set level, the controls start the charge pump and oil flows through the strainer and air eliminator.
2. Quality is checked
The S&W monitor checks the stream continuously. If water content is above the agreed limit, the diverter valve sends the oil back for treatment so only merchantable oil is delivered.
3. Quantity is measured
The custody transfer meter measures the oil. Temperature and pressure readings correct the volume to standard conditions, and the meter is proved against a prover to confirm its meter factor.
4. The ticket is produced
The sampler collects a composite sample for quality testing, and the flow computer or controller records the quantity and data for the measurement ticket.
What Fab Brings to a LACT Project
Our Shop
A 40,000-square-foot Houston shop with overhead cranes from 10 to 50 tons.
Fabrication In-House
Welding, machining, assembly and testing under one roof.
Instrumentation
Flow computers, instrumentation and complete metering packages.
Delivery & Service
Fast delivery, field service and 24-hour service to the Gulf Coast region. We ship worldwide.
What to Send Us
The more of your design we have, the faster we can quote. Helpful items include:
- Your P&ID, drawings or specification sheet
- The meter type and the components your design calls for
- Quantities and the timeline you are working to
- Where the unit will ship
For a quote, email sales@fabindustriesinc.com with your specifications or drawings, quantities, required dates and the ship-to location, or call 713-748-0799 (toll-free 800-227-6944). For anything else, email contactus@fabindustriesinc.com.
Planning a LACT Unit?
Request a quote, email sales@fabindustriesinc.com, or call 713-748-0799 or toll-free 800-227-6944. We provide 24-hour service to the Gulf Coast region.