Older meters evaluated against the latest edition of AGA Report No. 3, and upgraded where they fall short.

Recertification & Upgrades

Bring an Older Meter Up to Current Standards

Many meters in service today were built to earlier editions of the AGA standards. Fab Industries evaluates older meters, cleaning and inspecting them to see whether they meet the latest edition of AGA Report No. 3 (API MPMS 14.3.2), and if they do not, upgrades them to the latest AGA requirements.

Fab has been a Houston fabrication shop for the oil and gas industry for more than 40 years, starting in 1982 by refurbishing Daniel Senior Orifice meters. Our qualified welders, machinists and assembly and test crews do the evaluation, the upgrade work and the testing in-house.

What the Standard Covers

AGA Report No. 3, Part 2

AGA Report No. 3, Part 2 (API MPMS Chapter 14.3.2) sets the specification and installation requirements for concentric, square-edged, flange-tapped Orifice meters. For the meter tube and plate holder, it covers:

  • Internal diameter and roundness: the bore is measured at set locations upstream and downstream of the plate, with tighter tolerances close to the plate
  • Surface roughness and cleanliness: limits on the internal roughness of the tube, which must also be kept free of dirt, grease, liquids and other buildup
  • Pressure taps: tap hole size, location relative to the plate faces, and burr-free edges
  • Plate holder: the fitting or Orifice flanges must hold the plate concentric and square to the flow, with no seal protrusion into the bore and no bypass around the plate
  • Straight lengths: minimum upstream and downstream lengths of straight pipe, which depend on the diameter ratio (beta ratio) and on the fittings and valves upstream
  • Flow conditioners: the 19-tube bundle flow straightener with its specified construction and location, or other flow conditioners that have passed the standard’s performance test, which can reduce the straight length required

Why it matters for older meters

The standard leaves the decision to upgrade an existing installation to the parties involved, but notes that installations not upgraded may carry measurement bias from inadequate flow conditioning and upstream straight pipe lengths.

How We Evaluate a Meter

How We Upgrade a Meter

When a meter falls short, we upgrade it to the latest AGA requirements. Depending on what we find, that can include:

When an upgrade is not practical, we can fabricate a new meter tube or complete meter run. See AGA 3 Orifice Meter Tubes.

Hydrostatic Testing In-House

Upgraded meters are hydrostatically tested in our shop before they ship. AGA Report No. 3, Part 2 recommends measuring a fitting’s mechanical tolerances after it has been pressure-tested, and calls for checks for tap leakage and plate bypass after the meter run has been pressure-tested, so doing the hydrostatic test in-house lets those checks happen in our shop before the meter ships.

For a quote, email sales@fabindustriesinc.com with the meter size, pressure class, fitting type, any drawings, quantities, required dates and the ship-to location, or call 713-748-0799 (toll-free 800-227-6944). For anything else, email contactus@fabindustriesinc.com.

Planning a LACT Unit?

Request a quote, email sales@fabindustriesinc.com, or call 713-748-0799 or toll-free 800-227-6944. We provide 24-hour service to the Gulf Coast region.

×