Fab Industries, Inc. · Houston, Texas

Meter Skids

Metering skids fabricated in Houston around the meter technology that fits your application.

Fab Metering Skids

One Skid, Many Ways to Measure

Since 1982, Fab Industries has built metering skids for the oil and gas industry. We fabricate the meter tubes and meter runs at the heart of those skids, including Orifice, Ultrasonic, Coriolis, Turbine, Positive Displacement (PD), Vortex, and Venturi designs, in our 40,000-square-foot Houston facility. We also supply the flow computers and instrumentation, so we can deliver a complete, turnkey metering package.

Every meter technology has its own strengths and trade-offs. The right choice depends on the fluid, the flow range, how much pressure drop the system can afford, and how much room there is on the skid. The overview below explains how each type works and where it fits best.

Red meter runs with Orifice fittings on pipe stands in the Fab Industries shop
Orifice Meter Skids

Orifice Metering

An Orifice meter is a differential-pressure meter. A thin plate with a precisely bored, sharp-edged opening is held in an Orifice fitting or between flanges inside a meter tube. The plate creates a pressure drop, and flow is calculated from that differential pressure together with the line pressure, temperature, and gas properties.

Where It Fits Best

The long-standing workhorse of natural gas measurement. Orifice skids are a cost-effective, well-understood choice where flow stays within a moderate range and some pressure drop is acceptable. Because there are no moving parts, they are straightforward to inspect and service in the field. Fab fabricates Orifice meter tubes and repairs Orifice meters of all makes, including Daniel, PECO, FMC, Sure Shot, and Canalta.

Advantages

Considerations

Ultrasonic Meter Skids

Ultrasonic Metering

A multipath Ultrasonic meter is a full-bore spool fitted with pairs of transducers and an electronics module. Sound pulses are sent back and forth across the pipe at an angle; pulses traveling with the flow arrive slightly sooner than those traveling against it, and that time difference across several paths gives the average gas velocity.

Where It Fits Best

High-volume, high-pressure gas measurement such as pipeline and transmission meter stations, where the gas is dry and small measurement errors carry a large cost. Ultrasonic meters offer the widest turndown of the common gas meter types.

Advantages

Considerations

Coriolis Meter Skids

Coriolis Metering

A Coriolis meter measures mass flow directly. Fluid passes through one or more vibrating tubes, and the flow causes the tubes to twist slightly. Sensors at the inlet and outlet detect that twist as a phase shift proportional to mass flow, while the vibration frequency also indicates fluid density.

Where It Fits Best

Applications where mass, rather than volume, is what matters, in either liquid or gas service. Because the meter is not affected by flow profile, it fits compact skids where there is little room for straight runs. Coriolis meters are generally offered in smaller line sizes.

Advantages

Considerations

Turbine Meter Skids

Turbine Metering

A Turbine meter is a velocity meter. Flow passes through built-in straightening vanes and turns a bladed rotor on precision bearings; the rotor speed is proportional to flow velocity. A pickup counts the blades as pulses, and each pulse represents a known volume based on the meter’s calibration factor (K-factor).

Where It Fits Best

Clean, steady gas or liquid service where good accuracy and repeatability are needed at a moderate cost. In gas service, a Turbine meter’s usable range improves as line pressure increases.

Advantages

Considerations

Positive Displacement Meter Skids

Positive Displacement (PD) Metering

A Positive Displacement (PD) meter measures volume directly. The flowing liquid moves internal elements, such as gears, pistons, or rotating vanes, that trap and pass a fixed volume with every cycle. Counting the cycles gives the total volume delivered, and the speed of the cycles gives the flow rate.

Where It Fits Best

Liquid measurement where volume is the quantity of record, especially custody transfer of crude oil and other liquid hydrocarbons. PD meters are a common choice on LACT (lease automatic custody transfer) units and handle viscous liquids well.

Advantages

Considerations

Vortex Meter Skids

Vortex Metering

A Vortex meter places a bluff body, often called a shedder bar, across the flow. As the fluid passes it, small swirls called vortices form and break away from alternating sides of the bar. The rate at which they shed is proportional to flow velocity, and a sensor counts them so the meter’s electronics can calculate volumetric flow.

Where It Fits Best

Clean liquid, gas, or steam service with steady flow, where a rugged meter with no moving parts and a simple inline installation is wanted.

Advantages

Considerations

Venturi Meter Skids

Venturi Metering

A Venturi meter is a differential-pressure meter built as a section of pipe that gradually narrows to a throat and then gradually widens again. Flow is calculated from the pressure difference between the inlet and the throat, along with line pressure, temperature, and fluid properties.

Where It Fits Best

Applications where the simplicity of differential-pressure measurement is wanted but the permanent pressure loss of an Orifice plate is not. Venturi meters have long been used for gas flow in pipeline transmission. Fab fabricates Venturi tubes and Venturi meter runs.

Advantages

Considerations

Choosing the Right Meter

How the Technologies Compare

MeterMeasuresPressure LossRangeabilityStraight RunMoving Parts / UpkeepTypical Fit
OrificeVolume, from differential pressureHigherLimitedLong meter tube or flow conditionerNone; plate and tube inspectionCost-effective, proven gas measurement
UltrasonicVolume, from sound transit timeEssentially noneVery wideRequiredNone; built-in diagnosticsHigh-volume, high-pressure dry gas
CoriolisMass, directlyHigherWideNot requiredNone; periodic zero checksMass measurement in smaller lines, liquid or gas
TurbineVolume, from rotor speedModerateMedium; better at higher pressureShort, with integral conditioningRotor and bearings; flow calibrationClean, steady gas or liquid
Positive DisplacementVolume, directly in fixed incrementsModerate to higherWideLittle or noneInternal moving parts; periodic maintenanceLiquid custody transfer, LACT units
VortexVolume, from vortex frequencyModerateMedium; needs a minimum velocityRequiredNone; avoid pipe vibrationClean liquid, gas, or steam
VenturiVolume, from differential pressureLower than OrificeSet by differential pressure rangeRequired; less than OrificeNoneDP measurement with lower pressure loss

General guidance only. Actual performance depends on the specific meter, line size, fluid, and operating conditions.

Questions That Drive the Choice

Built to Your Specification

Whichever meter your application calls for, Fab fabricates the meter run, builds the skid around it, and can supply the flow computers and instrumentation for a complete, turnkey metering package. Need a different technology? We can build around other meter types on request.

We also build Regulator Skids and LACT units, supply parts and repair kits, and provide field service and meter rebuild and repair.

Send us your specifications and our team will put together a quote.

Sold on Their Own

Meter Runs & Meter Tubes

Fab also builds meter runs and meter tubes on their own, for customers who need the measurement section without a complete skid.

Meter tube: the measurement piping itself. For an Orifice meter, that is the straight upstream and downstream pipe sections and the Orifice fitting that holds the plate, with a flow conditioner where specified.

Meter run: the meter installed with its upstream and downstream piping, flow conditioning and end connections, ready to install in the line.

We build them to the piping requirements of the applicable AGA report (AGA Report No. 3 for Orifice, No. 7 for Turbine, No. 9 for Ultrasonic and No. 11 for Coriolis) and the meter manufacturer’s installation instructions, or to your specification.

Blue meter tube with an Orifice fitting and instrumentation, fabricated by Fab Industries

What We Build

Need a Metering Skid?

Request a quote or call 713-748-0799 or toll-free 800-227-6944. After-hours emergency service is available at 713-748-0799.

×
img

    Request a Quote

    Contact Info

    Phone number

    800-227-6944

    713-748-0799

    Email address

    Sales & Quotes: sales@fabindustriesinc.com

    General Inquiries: contactus@fabindustriesinc.com

    Address info

    6322 Long Dr. Houston, TX 77087